"Loading..."
Join the Burmon Revolution
FBC Code Approvals Click here

Load Table

Please note: these are single plate numbers.

FASTENER SCHEDULE2

Installation type

Limit State Design DF/SP

Factored Resistance (KD = 1.15)

Limit State Design S-P-F

Factored Resistance (KD = 1.15)

Corrosion Finish

Truss/Rafter

Single Plate

Burmon Stock No.
Ref No.
Steel Gauge
Qty
Type Burmon Screws
Qty
Type Burmon Screws
One Anchor
Uplift 160%
Lateral F1 160%
Lateral F2 160%
Uplift 160%
Lateral F1 160%
Lateral F2 160%
Galvinising

BHBSP

BHB

18

6

3 each side

BHH39

4

BSD39

k/N

7.4

4.2

3.4

5.8

3.3

2.6

G90

lbs

1663

947

764

1303

747

539

BHBSP

BHB

18

8

4 each side

BHH39

6

BSD39

k/N

11.1

6.32

5.1

8.7

4.95

4.0

G90

lbs

2493

1421

1146

1995

1137

917

  1. Allowable loads have been increased 60% for wind and seismic loads, no further increase shall be permitted.
  2. Minimum quantity of fasteners to be installed. Product has additional screw holes not needed to meet published allowable load of product.
  3. To view code report, click here or visit the code evaluation agency's website.

Technical Info & Downloads

Note: DWG, EASM, STEP and EPRT 3d Models may be viewed using free EDrawings Viewer software

Download the EDrawings Viewer

ProductProduct CodeDescriptionDrawing #PDFDWGEASMSTEPEPRTInstallation GuideBrochureInstallation Video
Hurricane Anchor for Single Sill Plate Connection to Truss/RafterBHBSPBHBSP