Product Reports

Intertek Engineering Report Download


Intertek 9-inch Bolt Analysis Report Download

Load Table

Limit State Design

Vertical

Lateral

Pullout

Uplift

Corrosion Finish

3290 Lbs.

3320 Lbs.

3515Lbs.

3690 Lbs.

Galvanizing G90
plus ceramic-coated bolts and washers salt tested 1000 hours for outside use

14.6 k/N

14.7 k/N

15.6 k/N

16.4 k/N

ICF Ledger Connectors - Burmon Building Products
* 5. ½ inch diameter, 3½ inch long Hex bolt
  1. Fasteners for wood ledgers provided with part
  2. Loads apply to ICF foam thickness of 3¼ or less.
  3. Concrete should have a minimum compressive rate of f'c = 2,500 psi (17.25 MPa)
  4. The bolts of BURMON-ICFWL must be no closer than 4 inches to the top of wall.
  5. * When attaching a deck to an ICF wall, place one ½ inch hex bolt 3½ inches long into each cylinder bolt hole as shown.
ICF Ledgers - Burmon Building Products
This table addresses vertical and pullout* load applications for foam thickness up to 3¼ inches. For foam thickness greater than 3¼ inches, contact our office for specific details.

Burmon ICFWL – Wood Ledger Spacing to Replace Anchor Bolts (inches)

Ledger Type

Model No.

½ inch Diameter Anchors at

⅝ inch Diameter Anchors at

(2) ⅝ inch Diameter Anchors at

(2) ¾ inch Diameter Anchors at

12in O.C.

24in O.C.

36in O.C.

48in O.C.

12in O.C.

24in O.C.

36in O.C.

48in O.C.

12in O.C.

24in O.C.

36in O.C.

48in O.C.

12in O.C.

24in O.C.

36in O.C.

48in O.C.

WOOD LEDGERS

2 x D.Fir-L/S-P-F

Burmon ICFWL

48in

48in

48in

48in

38in

48in

48in

48in

19in

38in

48in

48in

34in

48in

48in

48in

1¾ SCL

Burmon ICFWL

48in

48in

48in

48in

34in

48in

48in

48in

17in

34in

48in

48in

28in

48in

48in

48in

STEEL LEDGERS

16 gauge (0.060 inches)

Burmon ICFSL

20in

40in

48in

48in

16in

32in

48in

48in

14 gauge (0.075 inches)

Burmon ICFSL

16in

32in

48in

48in

13in

26in

39in

48in

ICFSL Load Table

Limit State Design

Vertical

Lateral

2890 Lbs.

2720 Lbs.

12.8 k/N

12 k/N

  1. Fasteners for steel ledgers provided with part
  2. Minimum steel ledger thickness is 16 gauge, 54mm steel ledger
  3. Loads apply to ICF foam thickness of 3¼ or less.
  4. Concrete should have a minimum compressive rate of f'c = 2,500 psi (17.25 MPa)
  5. The bolts of BURMON-ICFSL must be no closer than 4 inches to the top of wall.
ICF Ledgers - Burmon Building Products

The following spacing tables are an alternative to the ICFWL spacing to replace the building code-prescribed anchor bolt spacing for vertical loads only. They provide the recommended spacing of the ICFWL Ledger Connectors based on the Factored Vertical Resistance of the connector, the load on the floor and the span of the joist. The Designer must determine the design load, the ledger design and the joist design. This table is useful if the Designer already has loads and spans, but not necessarily anchor bolt spacing.

Spacing for Burmon ICFWL (in.)

* Values in the cells highlighted represent the maximum allowable spacing of 48".

Specified Load (psf)

Joist Span (ft.)

Live

Dead

10

12

14

16

18

20

22

24

26

28

30

32

40

10

48

48

48

46

41

37

33

31

28

26

24

23

15

48

48

48

42

38

34

31

28

26

24

22

21

20

48

48

45

39

35

31

28

26

24

22

21

19

25

48

48

42

37

32

29

26

24

22

21

19

18

30

48

46

39

34

30

27

25

23

21

19

18

17

50

10

48

48

44

38

34

30

28

25

23

22

20

19

20

48

45

38

33

30

27

24

22

20

19

18

16

30

48

40

34

30

26

24

21

20

18

17

16

15

40

43

36

30

27

24

21

19

18

16

15

14

13

100

10

33

27

23

20

18

16

15

13

12

20

30

25

22

19

17

15

14

12

30

28

24

20

18

16

14

13

12

40

27

22

19

16

15

13

12

Spacing for Burmon ICFSL (in.)

Uniform Loads

Joist Span (ft.)

Dead Load (psf)

Live Loads (psf)

10

12

14

16

18

20

22

24

26

10

40

36

36

36

36

36

35

31

29

27

15

40

36

36

36

36

35

31

28

26

24

20

40

36

36

36

36

32

29

26

24

22

10

60

36

36

36

31

27

24

22

21

19

20

60

36

36

31

27

24

21

19

18

16

30

60

36

32

27

24

21

19

18

16

15

  1. Values shown are maximum spacing distances (inches) based on two-span ledger and simple supported joists. It does not consider concentrated loads. The Engineer of Record can modify the spacing accordingly for other conditions.
  2. Joist and ledger are to be designed by others.
  3. Spacing tables address vertical load applications only. If the connection is designed to resist simultaneous lateral loads, spacing may decrease. Contact Burmon Building Products for additional information.
  4. The ICFWL must be installed no closer than 4" below the top of wall to achieve the connector spacing.
  5. The maximum distance between the end of the ledger and the first ICFWL is 12" as per the recommended splicing installation.
  6. Tables above assume Principal Loads only with Importance Factor = 1.00. For other cases adjust spacing accordingly.

Technical Info & Downloads

Note: DWG, EASM, STEP and EPRT 3d Models may be viewed using free EDrawings Viewer software

Download the EDrawings Viewer

ProductProduct CodeDescriptionDrawing #PDFDWGEASMSTEPEPRTInstallation GuideBrochureInstallation Video
Burmon ICF Wood LedgerICFWLICFWL Assembled7
Burmon ICF Wood LedgerICFWLICFWL Ledger Connector to ICF Wall Connection8
Burmon ICF Wood LedgerICFWLWood Ledger to Burmon ICFWL Connection9
Burmon ICF Wood LedgerICFWLSingle ICFWL Template10
Burmon ICF Wood LedgerICFWLUsing the ICFWL Template to mark out bolt holes11